Bhowra-West Colliery
Statistical Intelligence • Hybrid Detection Engine

Statistical Anomaly Detection & Explainable Risk Engine

Multi-transducer sensor fusion, rolling Z-score persistence analysis, and Pearson inter-station correlation.

DEMO SYNTHETICModel: EWMA + Robust Z-Score (v2.1)Normal[L0]
DGMS Safety-Critical Decision Support Standard: This platform performs statistical anomaly detection and evidence-based risk assessment. It detects abnormal rates of change, multi-station persistence, and cross-modality correlation. It does not claim deterministic collapse prediction.
Composite Risk Index
0.78 / 1.00
Baseline nominal: < 0.40
Spatial Correlation
r = +0.84
Pearson inter-station co-variance
Persistence Window
18 seconds
Transient vibration filter: 45s
Modality Agreement
88%
Tilt • Disp • PPV agreement
Focus District:
Focus Node: SN-102
Pearson Spatial Correlation Matrix (P-101)Inter-Station Concordance
StationSN-101SN-102SN-103SN-104
SN-1011.000.880.760.42
SN-1020.881.000.820.51
SN-1030.760.821.000.63
SN-1040.420.510.631.00

Values $r \ge 0.80$ indicate multi-station spatial deformation basin formation rather than single-sensor transient drift.

Transducer Concordance (SN-102)Demonstration Model

Biaxial Tilt Slope (Tilt X)

Dual MEMS Inclinometer

12.40 arcsec

Limit: 3.0 mm/m

Borehole Extensometer (DISP_Z)

Deep Strata Anchor

18.50 mm

Threshold: 30.0 mm

Microseismic Vibration (VIB_RMS)

Velocity Geophone

2.10 mm/s

Limit: 5.0 mm/s

Pillar Strain Gauge (STRAIN)

Roof Bolt Axial Tension

420.0 µε

Nominal: < 600 µε

Anomaly Detection Model Configuration & Rejection Filters

Model ComponentAlgorithmSample WindowRejection FilterRegulatory Reference
Baseline SmoothingExponentially Weighted Moving Average (EWMA)α = 0.20 (15-sample window)High-frequency machinery vibration filterDGMS TC 4/2017
Outlier ScoringMedian Absolute Deviation (Robust Z-Score)N = 50 samples rollingRejects single-point transient spikes (|z| < 2.5)CMPDI Technical Standard
Spatial Cross-CheckPearson Bivariate Inter-Node CorrelationAdjacent nodes in extraction panelSingle-node failure requires second-node corroborationDGMS CMR Reg 112